DLM200 specifications

(Click Picture for close up)
  DLM200 series Release Notes in MS Word Format
Line Speeds: 75-57.6k  bps Asynchronous, 75-64k bps Synchronous, External
 
Protocols: Asynchronous, BSC, SDLC/HDLC, Isochronous
 
Accessories: Everythingl you need: 
2 compartment carrying case, wall transformer, batteries, 102 LED Break out Box (BOB100), 9 pin to 25 pin adapters, manual plus quick start instructions.

Auto Configuration: Within 20 characters received, determines protocol, bit rates, number of bits per character, sync character, parity and then automatically sets the proper parameters and presents captured data to the screen
 



Bit/Block Transmission Tests: RD/TD buffer FOX All bits user string1/2 FOX2 00, FF Patterns 511 ASCII set 0-FF
 
Buffer:  128K bytes of non-volatile RAM for transmitted data and received data
 
Saved Data: Saves/displays state of the modem control lines with each byte posted to the capture buffer
 
Triggers and Filters: Triggers can be set to start or stop data capture on user-defined strings of up to 80 bytes or on interface signal pattern. Start triggers can be automatically reset after occurrence of stop trigger by DLM200
 
Physical : 9.25 x 5.50 x 1.37 inches; 23 ounces 23.5 x 13.5 x 3.3 centimeters; 630 grams
 
Keyboard: Full 64 key QWERTY keyboard PLUS PC style directional keypad
 
Display: 8 line by 30/40 Graphic Display
 
Analysis:  Average times between triggers to the millisecond (up to four hours) to measure human, computer and communications line performance

Throughput Tests: Analysis BERT performance statistics and performance calculations.
 
Help: Online printable help for all functions
 
Interfaces: RS-232. (RS422, V.35 optional)
 
Parity: Odd, Even, None
 
Codes: ASCII, EBCDIC, BAUDOT, IPARS
 
Power: 9-volt battery ( 9 hours with alkaline), transformer

Click here to receive more information